Difference between revisions of "Current Server Models"

From IVS Wiki
Jump to: navigation, search
(Created page with "<table class="server_information_table"> <tr class="red"> <th>Model Name</th> <th>R1Z4S</th> <th>R1Z8S</th> <th>R1Z16S</th> <th>R1Z40D</th> <th>R2Z80...")
 
 
(15 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
{{Aside - Helpful | content = To see spec sheets for our current servers, please [https://www.ipivs.com/products/valt-appliances click here].}}
 +
 
<table class="server_information_table">
 
<table class="server_information_table">
 +
  <!-- HEADER -->
 
   <tr class="red">
 
   <tr class="red">
 
     <th>Model Name</th>
 
     <th>Model Name</th>
     <th>R1Z4S</th>
+
     <th>R1A4S</th>
     <th>R1Z8S</th>
+
     <th>R1A8S</th>
     <th>R1Z16S</th>
+
     <th>R1A16S</th>
     <th>R1Z40D</th>
+
     <th>R1A40S</th>
     <th>R2Z80D</th>
+
     <th>R2A80S</th>
     <th>T4Z12S</th>
+
     <th>T1A2S</th>
 +
    <th>T4A12S</th>
 
   </tr>
 
   </tr>
 +
 +
  <!-- IMAGES -->
 
   <tr>
 
   <tr>
 
     <td>Image</td>
 
     <td>Image</td>
     <td>{{img - button | file = 1uServerFront.jpg | width = 200px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R1Z4S%20Server%20Spec%20Sheet.pdf}}</td>
+
     <td colspan="4">{{img - button | file = 1uServerFront.jpg | width = 200px | link = https://app.storylane.io/share/x8qcsbfkhqhr}}</td>
    <td>{{img - button | file = 1uServerFront.jpg | width = 200px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R1Z8S%20SERVER%20SPEC%20SHEET.pdf}}</td>
+
     <td>{{img - button | file = 2uServerFront.jpg | width = 200px | link = https://app.storylane.io/share/taguq5devkzn}}</td>
    <td>{{img - button | file = 1uServerFront.jpg | width = 200px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R1Z16S%20SERVER%20SPEC%20SHEET%20.pdf}}</td>
+
     <td>{{img - no click | file = T1A2S.png | width = 100px}}</td>
     <td>{{img - button | file = 2uServerFront.jpg | width = 200px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R1Z40D%20Server%20Spec%20Sheet.pdf}}</td>
+
     <td>{{img | file = T350ServerFront.png | width = 100px}}</td>
     <td>{{img - button | file = 2uServerFront.jpg | width = 200px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R2Z80D%20Server%20Spec%20Sheet.pdf}}</td>
 
     <td>{{img - button | file = T350ServerFront.png | width = 100px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/SpecSheets/T4Z12S_PS21_1122.pdf}}</td>
 
  </tr>
 
  <tr>
 
    <td>Spec Sheet</td>
 
    <td>{{img - button | file = Pdf icon.png | width = 50px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R1Z4S%20Server%20Spec%20Sheet.pdf}}</td>
 
    <td>{{img - button | file = Pdf icon.png | width = 50px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R1Z8S%20SERVER%20SPEC%20SHEET.pdf}}</td>
 
    <td>{{img - button | file = Pdf icon.png | width = 50px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R1Z16S%20SERVER%20SPEC%20SHEET%20.pdf}}</td>
 
    <td>{{img - button | file = Pdf icon.png | width = 50px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R1Z40D%20Server%20Spec%20Sheet.pdf}}</td>
 
    <td>{{img - button | file = Pdf icon.png | width = 50px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/documents/R2Z80D%20Server%20Spec%20Sheet.pdf}}</td>
 
    <td>{{img - button | file = Pdf icon.png | width = 50px | link = https://5881113.fs1.hubspotusercontent-na1.net/hubfs/5881113/SpecSheets/T4Z12S_PS21_1122.pdf}}</td>
 
 
   </tr>
 
   </tr>
 +
 +
  <!-- COMPLIANCE (placeholders) -->
 
   <tr>
 
   <tr>
 
     <td>Compliance</td>
 
     <td>Compliance</td>
     <td>[https://dl.dell.com/rdoc/dell%20poweredge%20r240%20e57s%20e57s001%20dell%20regulatory%20and%20environmental%20datasheet%20en-us.pdf Compliance] [https://dl.dell.com/rdoc/dell%20poweredge%20r240%20e57s%20e57s001%20european%20union%20-%20declaration%20of%20conformity%20en-us.pdf EU] [https://dl.dell.com/rdoc/dell%20poweredge%20r240%20e57s%20e57s001%20united%20kingdom%20-%20declaration%20of%20conformity%20en-us.pdf UK]</td>
+
     <td>[https://dl.dell.com/RDOC/Dell%20PowerEdge%20R260%20E104S%20E104S001%20DELL%20Regulatory%20and%20Environmental%20Datasheet%20en-us.pdf Compliance] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R260%20E104S%20E104S001%20EUROPEAN%20UNION%20-%20Declaration%20of%20Conformity%20en-us.pdf EU] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R260%20E104S%20E104S001%20UNITED%20KINGDOM%20-%20Declaration%20of%20Conformity%20en-us.pdf UK]</td>
     <td>[https://dl.dell.com/rdoc/dell%20emc%20poweredge%20r340%20e58s%20e58s001%20dell%20regulatory%20and%20environmental%20datasheet%20en-us.pdf Compliance] [https://dl.dell.com/rdoc/dell%20emc%20poweredge%20r340%20e58s%20e58s001%20european%20union%20-%20declaration%20of%20conformity%20en-us.pdf EU] [https://dl.dell.com/rdoc/dell%20emc%20poweredge%20r340%20e58s%20e58s001%20united%20kingdom%20-%20declaration%20of%20conformity%20en-us.pdf UK]</td>
+
     <td>[https://dl.dell.com/RDOC/Dell%20PowerEdge%20R360%20E77S%20E77S002%20DELL%20Regulatory%20and%20Environmental%20Datasheet%20en-us.pdf Compliance] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R360%20E77S%20E77S002%20EUROPEAN%20UNION%20-%20Declaration%20of%20Conformity%20en-us.pdf EU] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R360%20E77S%20E77S002%20UNITED%20KINGDOM%20-%20Declaration%20of%20Conformity%20en-us.pdf UK]</td>
     <td>[https://dl.dell.com/rdoc/dell%20poweredge%20r440%20e45s%20e45s001%20dell%20regulatory%20and%20environmental%20datasheet%20en-us.pdf Compliance] [https://dl.dell.com/rdoc/dell%20poweredge%20r440%20e45s%20e45s001%20european%20union%20-%20declaration%20of%20conformity%20en-us.pdf EU] [https://dl.dell.com/rdoc/dell%20emc%20poweredge%20r440%20e45s%20e45s001%20united%20kingdom%20-%20declaration%20of%20conformity%20en-us.pdf UK]</td>
+
     <td>[https://dl.dell.com/RDOC/Dell%20PowerEdge%20R470%20E108S%20E108S001%20DELL%20Regulatory%20and%20Environmental%20Datasheet%20en-us.pdf Compliance] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R470%20E108S%20E108S001%20EUROPEAN%20UNION%20-%20Declaration%20of%20Conformity%20en-us.pdf EU] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R470%20E108S%20E108S001%20UNITED%20KINGDOM%20-%20Declaration%20of%20Conformity%20en-us.pdf UK]</td>
     <td colspan="2">[https://dl.dell.com/rdoc/dell%20poweredge%20r540%20e46s%20e46s001%20dell%20regulatory%20and%20environmental%20datasheet%20en-us.pdf Compliance] [https://dl.dell.com/rdoc/dell%20poweredge%20r540%20e46s%20e46s001%20european%20union%20-%20declaration%20of%20conformity%20en-us.pdf EU] [https://dl.dell.com/rdoc/dell%20poweredge%20r540%20e46s%20e46s001%20united%20kingdom%20-%20declaration%20of%20conformity%20en-us.pdf UK]</td>
+
     <td>[https://dl.dell.com/RDOC/Dell%20PowerEdge%20R470%20E108S%20E108S001%20DELL%20Regulatory%20and%20Environmental%20Datasheet%20en-us.pdf Compliance] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R470%20E108S%20E108S001%20EUROPEAN%20UNION%20-%20Declaration%20of%20Conformity%20en-us.pdf EU] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R470%20E108S%20E108S001%20UNITED%20KINGDOM%20-%20Declaration%20of%20Conformity%20en-us.pdf UK]</td>
  <td>[https://dl.dell.com/rdoc/dell%20emc%20poweredge%20t350%20e78s%20e78s001%20dell%20regulatory%20and%20environmental%20datasheet%20en-us.pdf Compliance] [https://dl.dell.com/rdoc/dell%20emc%20poweredge%20t350%20e78s%20e78s001%20european%20union%20-%20declaration%20of%20conformity%20en-us.pdf EU] [https://dl.dell.com/rdoc/dell%20emc%20poweredge%20t350%20e78s%20e78s001%20united%20kingdom%20-%20declaration%20of%20conformity%20en-us.pdf UK]</td>
+
    <td>[https://dl.dell.com/RDOC/Dell%20PowerEdge%20R570%20E109S%20E109S001%20DELL%20Regulatory%20and%20Environmental%20Datasheet%20en-us.pdf Compliance] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20R570%20E109S%20E109S001%20EUROPEAN%20UNION%20-%20Declaration%20of%20Conformity%20en-us.pdf EU]</td>
 +
    <td>[https://dl.dell.com/RDOC/Dell%20OptiPlex%20Micro%207020%20D15U%20D15U005%20DELL%20Regulatory%20and%20Environmental%20Datasheet%20en-us.pdf Compliance] [https://dl.dell.com/RDOC/Dell%20OptiPlex%20Micro%207020%20D15U%20D15U005%20EUROPEAN%20UNION%20-%20Declaration%20of%20Conformity%20en-us.pdf EU] [https://dl.dell.com/RDOC/Dell%20OptiPlex%20Micro%207020%20D15U%20D15U005%20UNITED%20KINGDOM%20-%20Declaration%20of%20Conformity%20en-us.pdf UK]</td>
 +
    <td>[https://dl.dell.com/RDOC/Dell%20PowerEdge%20T160%20E105S%20E105S001%20DELL%20Regulatory%20and%20Environmental%20Datasheet%20en-us.pdf Compliance] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20T160%20E105S%20E105S001%20EUROPEAN%20UNION%20-%20Declaration%20of%20Conformity%20en-us.pdf EU] [https://dl.dell.com/RDOC/Dell%20PowerEdge%20T160%20E105S%20E105S001%20UNITED%20KINGDOM%20-%20Declaration%20of%20Conformity%20en-us.pdf UK]</td>
 
   </tr>
 
   </tr>
 +
 +
  <!-- CAPACITY & STORAGE -->
 
   <tr class="orange">
 
   <tr class="orange">
     <td colspan="7" style="background-color: var(--ivsGrey);color: white;font-weight:bolder">CAPACITY AND STORAGE</td>
+
     <td colspan="8" style="background-color: var(--ivsGrey);color: white;font-weight:bolder">CAPACITY AND STORAGE</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Cameras*</td>
 
     <td>Cameras*</td>
 
     <td>10</td>
 
     <td>10</td>
     <td>20</td>
+
     <td>15</td>
     <td>30</td>
+
     <td>25</td>
     <td colspan="2">60</td>
+
     <td colspan="2">50</td>
     <td>20</td>
+
     <td>5</td>
 +
    <td>15</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Video Storage</td>
 
     <td>Video Storage</td>
Line 53: Line 57:
 
     <td>40 TB</td>
 
     <td>40 TB</td>
 
     <td>80 TB</td>
 
     <td>80 TB</td>
 +
    <td>2 TB</td>
 
     <td>12 TB</td>
 
     <td>12 TB</td>
 
   </tr>
 
   </tr>
 +
 
   <tr title="* Estimated retention hours for use with 1080P cameras. For 720P cameras multiply by 2.">
 
   <tr title="* Estimated retention hours for use with 1080P cameras. For 720P cameras multiply by 2.">
 
     <td>Video Capacity*</td>
 
     <td>Video Capacity*</td>
Line 62: Line 68:
 
     <td>20,000 Hours</td>
 
     <td>20,000 Hours</td>
 
     <td>40,000 Hours</td>
 
     <td>40,000 Hours</td>
 +
    <td>1,000 Hours</td>
 
     <td>6,000 Hours</td>
 
     <td>6,000 Hours</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>OS Redundancy</td>
 
     <td>OS Redundancy</td>
     <td colspan="6">RAID 1</td>
+
    <td>RAID 1 SSD</td>
 +
     <td colspan="4">RAID 1</td>
 +
    <td>None</td>
 +
    <td>RAID 1</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Video Storage Redundancy</td>
 
     <td>Video Storage Redundancy</td>
 +
    <td colspan="2">RAID 1</td>
 +
    <td>RAID 5</td>
 +
    <td colspan="2">RAID 10</td>
 +
    <td>None</td>
 
     <td>RAID 1</td>
 
     <td>RAID 1</td>
    <td colspan="2">RAID 5</td>
 
    <td>RAID 10</td>
 
    <td>RAID 6</td>
 
 
   </tr>
 
   </tr>
 +
 +
  <!-- PROCESSING & MEMORY -->
 
   <tr class="orange">
 
   <tr class="orange">
     <td colspan="7" style="background-color: var(--ivsGrey);color: white;font-weight:bolder">PROCESSING AND MEMORY</td>
+
     <td colspan="8" style="background-color: var(--ivsGrey);color: white;font-weight:bolder">PROCESSING AND MEMORY</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>CPU</td>
 
     <td>CPU</td>
     <td>Intel Xeon E-2336</td>
+
     <td>Intel Xeon E-2436</td>
     <td>Intel Xeon E-2356G</td>
+
     <td>Intel Xeon E-2456</td>
     <td>Intel Xeon Silver 4310</td>
+
     <td>Intel Xeon 6 Performance 6505P</td>
     <td colspan="2">Xeon Silver 4316</td>
+
     <td colspan="2">Intel Xeon 6 Performance 6527P</td>
     <td>Intel Xeon E-2356G</td>
+
    <td>Intel Core Ultra 5 235</td>
 +
     <td>Intel Xeon E-2436</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>L3 Cache</td>
 
     <td>L3 Cache</td>
     <td colspan="2">12 MB</td>
+
     <td colspan="2">18 MB</td>
 +
    <td>48 MB</td>
 +
    <td colspan="2">144 MB</td>
 +
    <td>24 MB</td>
 
     <td>18 MB</td>
 
     <td>18 MB</td>
    <td colspan="2">30 MB</td>
 
  <td>12 MB</td>
 
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Cores(Threads)</td>
 
     <td>Cores(Threads)</td>
 
     <td colspan="2">6(12)</td>
 
     <td colspan="2">6(12)</td>
 
     <td>12(24)</td>
 
     <td>12(24)</td>
     <td colspan="2">20(40)</td>
+
     <td colspan="2">24(48)</td>
     <td colspan="2">6(12)</td>
+
    <td>14(20)</td>
 +
     <td>6(12)</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
     <td>Base Clock(Boost Clock)</td>
+
     <td>Base Clock <br>(Boost Clock)</td>
     <td>2.9(4.8) Ghz</td>
+
     <td>2.9 Ghz</td>
     <td>3.2(5.0) Ghz</td>
+
     <td>3.3 Ghz</td>
     <td>2.1(3.3) Ghz</td>
+
     <td>2.2 Ghz</td>
     <td colspan="2">2.3(3.4) Ghz</td>
+
     <td colspan="2">3.0 Ghz</td>
     <td>3.2 Ghz</td>
+
     <td>2.9 Ghz</td>
 +
    <td>2.9 Ghz</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Memory</td>
 
     <td>Memory</td>
     <td>8 GB</td>
+
     <td colspan="2">16 GB</td>
 +
    <td colspan="3">128 GB</td>
 
     <td>16 GB</td>
 
     <td>16 GB</td>
 
     <td>32 GB</td>
 
     <td>32 GB</td>
    <td colspan="2">64 GB</td>
 
    <td>16 GB</td>
 
 
   </tr>
 
   </tr>
 +
 +
  <!-- POWER & THERMALS -->
 
   <tr class="orange">
 
   <tr class="orange">
     <td colspan="7" style="background-color: var(--ivsGrey);color: white;font-weight:bolder">POWER AND THERMALS</td>
+
     <td colspan="8" style="background-color: var(--ivsGrey);color: white;font-weight:bolder">POWER AND THERMALS</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>PSU Rating</td>
 
     <td>PSU Rating</td>
     <td>450 W</td>
+
     <td>450W</td>
     <td>600 W</td>
+
     <td>600W</td>
     <td>550 W</td>
+
     <td colspan="3">800W</td>
     <td colspan="2">800 W</td>
+
     <td>280W</td>
     <td>350 W</td>
+
     <td>500W</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
     <td>Power Consumption</td>
+
     <td>Avg. Power Consumption</td>
 
     <td colspan="2">160 W</td>
 
     <td colspan="2">160 W</td>
     <td>283 W</td>
+
     <td colspan="2">283 W</td>
     <td colspan="2">274 W</td>
+
     <td>274 W</td>
 +
    <td>Not Available</td>
 
     <td>144 W</td>
 
     <td>144 W</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>PSU Redundancy</td>
 
     <td>PSU Redundancy</td>
 
     <td>No</td>
 
     <td>No</td>
     <td colspan="5">Yes</td>
+
     <td colspan="4">Yes</td>
 +
    <td colspan="2">No</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Thermal Output</td>
 
     <td>Thermal Output</td>
     <td colspan="4">545.9 BTU/hr</td>
+
     <td colspan="2">546 BTU/hr</td>
     <td colspan="1">934.9 BTU/hr</td>
+
    <td>965 BTU</td>
     <td>491.3 BTU/hr</td>
+
    <td>965 BTU/hr</td>
 +
    <td>935 BTU/hr</td>
 +
     <td>338 BTU/hr</td>
 +
     <td>491 BTU/hr</td>
 
   </tr>
 
   </tr>
 +
 +
  <!-- FORM FACTOR -->
 
   <tr class="orange">
 
   <tr class="orange">
     <td colspan="7" style="background-color: var(--ivsGrey);color: white;font-weight:bolder">FORM FACTOR</td>
+
     <td colspan="8" style="background-color: var(--ivsGrey);color: white;font-weight:bolder">FORM FACTOR</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
     <td>Rack Space</td>
+
     <td>Rack Space / Form Factor</td>
 
     <td colspan="4">1U</td>
 
     <td colspan="4">1U</td>
 
     <td>2U</td>
 
     <td>2U</td>
 +
    <td>Micro Tower</td>
 
     <td>Mid Tower</td>
 
     <td>Mid Tower</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Height</td>
 
     <td>Height</td>
     <td colspan="4">1.7"</td>
+
     <td colspan="2">1.7"</td>
     <td>3.5"</td>
+
    <td colspan="2">1.69"</td>
     <td>14.54"</td>
+
     <td>3.42"</td>
 +
    <td>8.11"</td>
 +
     <td>13.09"</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Width</td>
 
     <td>Width</td>
     <td colspan="5">17.08"</td>
+
     <td colspan="2">17.08"</td>
     <td>6.88"</td>
+
     <td colspan="2">19.0"</td>
 +
    <td>18.98"</td>
 +
    <td>3.12"</td>
 +
    <td>5.21"</td>
 
   </tr>
 
   </tr>
 +
 
   <tr>
 
   <tr>
 
     <td>Depth</td>
 
     <td>Depth</td>
 
     <td colspan="2">23.45"</td>
 
     <td colspan="2">23.45"</td>
     <td>28.13"</td>
+
     <td colspan="2">32.16"</td>
     <td colspan="2">27.31"</td>
+
     <td>31.59"</td>
     <td>22.87"</td>
+
    <td>7.00"</td>
 +
     <td>16.09"</td>
 
   </tr>
 
   </tr>
 
</table>
 
</table>

Latest revision as of 11:13, 17 February 2026

🕮
To see spec sheets for our current servers, please click here.
Model Name R1A4S R1A8S R1A16S R1A40S R2A80S T1A2S T4A12S
Image 1uServerFront.jpg 2uServerFront.jpg T1A2S.png T350ServerFront.png
Compliance Compliance EU UK Compliance EU UK Compliance EU UK Compliance EU UK Compliance EU Compliance EU UK Compliance EU UK
CAPACITY AND STORAGE
Cameras* 10 15 25 50 5 15
Video Storage 4 TB 8 TB 16 TB 40 TB 80 TB 2 TB 12 TB
Video Capacity* 2,000 Hours 4,000 Hours 8,000 Hours 20,000 Hours 40,000 Hours 1,000 Hours 6,000 Hours
OS Redundancy RAID 1 SSD RAID 1 None RAID 1
Video Storage Redundancy RAID 1 RAID 5 RAID 10 None RAID 1
PROCESSING AND MEMORY
CPU Intel Xeon E-2436 Intel Xeon E-2456 Intel Xeon 6 Performance 6505P Intel Xeon 6 Performance 6527P Intel Core Ultra 5 235 Intel Xeon E-2436
L3 Cache 18 MB 48 MB 144 MB 24 MB 18 MB
Cores(Threads) 6(12) 12(24) 24(48) 14(20) 6(12)
Base Clock
(Boost Clock)
2.9 Ghz 3.3 Ghz 2.2 Ghz 3.0 Ghz 2.9 Ghz 2.9 Ghz
Memory 16 GB 128 GB 16 GB 32 GB
POWER AND THERMALS
PSU Rating 450W 600W 800W 280W 500W
Avg. Power Consumption 160 W 283 W 274 W Not Available 144 W
PSU Redundancy No Yes No
Thermal Output 546 BTU/hr 965 BTU 965 BTU/hr 935 BTU/hr 338 BTU/hr 491 BTU/hr
FORM FACTOR
Rack Space / Form Factor 1U 2U Micro Tower Mid Tower
Height 1.7" 1.69" 3.42" 8.11" 13.09"
Width 17.08" 19.0" 18.98" 3.12" 5.21"
Depth 23.45" 32.16" 31.59" 7.00" 16.09"