Difference between revisions of "Start/Stop Button"

From IVS Wiki
Jump to: navigation, search
Line 29: Line 29:
 
You will need to log into the software with admin rights and navigate to the admin section then click on rooms.
 
You will need to log into the software with admin rights and navigate to the admin section then click on rooms.
  
[[File:io.jpg]]
+
[[File:Start_stop_config.png]]
#) Select a room
+
#) Select the room
 
#) Check the Use I/O box
 
#) Check the Use I/O box
 
#) Select what camera the I/O wiring is tied into
 
#) Select what camera the I/O wiring is tied into
 
#) Select a user - All I/O recordings in that room will be considered authored by that user
 
#) Select a user - All I/O recordings in that room will be considered authored by that user
 +
#) Select Start/Stop in the command field
 +
#) Enter port number 1
 
#) If it is a PTZ camera you can have the camera move to a preset at the start of the recording
 
#) If it is a PTZ camera you can have the camera move to a preset at the start of the recording
 
#) Press Save to enable I/O button recordings
 
#) Press Save to enable I/O button recordings
 +
 +
==Camera Configuration==
 +
#) Navigate to the IP of the camera
 +
#) (In the old navigation view) Go to Setup in the top right; then System Options
 +
#) For Allow Password Type, select Unencrypted Only
 +
#
 +
 +
#) (In the new navigation view) Go to Settings; then System; then Plain Config
 +
#
 +
#) Scroll and select Network
 +
#) Under HTTP, Authentication Policy, select Basic. Scroll to click Save
 +
#

Revision as of 16:40, 19 February 2019

Hardware Configuration

First wire the button to the desired camera's IO phoenix connector. If you are using our buttons, the wires should be connected to the back of the button as shown in the diagram below.

BTNDiag.jpg

Button Phoenix Connector
NO Pin 1
+ Pin 2
C Pin 3
- Pin 4


We recommend wiring the buttons using 22/4 as shown below:

Wiring Diagram3.jpg

Software Configuration

You will need to log into the software with admin rights and navigate to the admin section then click on rooms.

Start stop config.png

  1. ) Select the room
  2. ) Check the Use I/O box
  3. ) Select what camera the I/O wiring is tied into
  4. ) Select a user - All I/O recordings in that room will be considered authored by that user
  5. ) Select Start/Stop in the command field
  6. ) Enter port number 1
  7. ) If it is a PTZ camera you can have the camera move to a preset at the start of the recording
  8. ) Press Save to enable I/O button recordings

Camera Configuration

  1. ) Navigate to the IP of the camera
  2. ) (In the old navigation view) Go to Setup in the top right; then System Options
  3. ) For Allow Password Type, select Unencrypted Only
  1. ) (In the new navigation view) Go to Settings; then System; then Plain Config
  2. ) Scroll and select Network
  3. ) Under HTTP, Authentication Policy, select Basic. Scroll to click Save