− | + | =Default IP= | |
− | + | By default the all Epiphans can always be accessed by the following IP scheme. | |
+ | '''''Note: If multiple encoders are on the network, your connection might switch between multiple of the encoders.''''' | ||
− | https://www.epiphan.com/products/vgadvi-broadcaster/vgadvi-broadcaster-downloads/ | + | * '''IP Address:''' <code>192.168.255.250</code> |
+ | * '''Netmask:''' <code>255.255.255.252</code> | ||
+ | * '''User Name:''' <code>admin</code> | ||
+ | * '''Password:''' your admin password (by default set to no password) | ||
+ | |||
+ | =Connect to a New Encoder= | ||
+ | |||
+ | To access the VGADVI Broadcaster web interface via the persistent static IP address: | ||
+ | |||
+ | # Record the network settings of the workstation being used to connect to the VGADVI Broadcaster so that they can be restored later. | ||
+ | # Temporarily change the network configuration on the workstation to the following: | ||
+ | #* Use Static IP assignment | ||
+ | #*# '''IP address:''' <code>192.168.255.249</code> | ||
+ | #*# '''Subnet mask:''' <code>255.255.255.252</code> | ||
+ | # Establish an Ethernet connection between the VGADVI Broadcaster and the workstation by one of the following methods: | ||
+ | #* Connect the device to a local Ethernet network shared with the workstation. | ||
+ | #* Connect the device directly to the workstation’s Ethernet port using either a regular or a crossover Ethernet cable. | ||
+ | # Start a web browser on the workstation and browse to: <code>http://192.168.255.250/admin/</code> | ||
+ | # Log in as the administrator user with the user name admin and the admin password (by default there is no password); the web interface page opens. | ||
+ | # Click the Networking link in the Configuration menu. | ||
+ | |||
+ | =Configuring the Encoder= | ||
+ | |||
+ | The following camera settings should be enabled prior to adding the camera to the VALT system. | ||
+ | |||
+ | : 1.) Use the Epiphan Discovery Tool to find the VGABroadcaster device. | ||
+ | |||
+ | :: https://www.epiphan.com/products/vgadvi-broadcaster/vgadvi-broadcaster-downloads/ | ||
[[File:ep_1.jpg|400px]] | [[File:ep_1.jpg|400px]] | ||
− | 2) Click on Web | + | : 2.) Click on '''Web Config''' using the Discovery tool, or enter the ''<ipaddress>/admin'' in a web browser to access the configuration menu. The username should be admin, with a blank password. Click on the '''Access''' button. |
[[File:ep_2.jpg|800px]] | [[File:ep_2.jpg|800px]] | ||
− | 3) Click on the | + | : 3.) Click on the '''Network''' button and select ''Use Static Address'', ''Set the IP'', ''Network Mask'', ''Gateway'' & ''DNS'' information, then click '''Apply''' as shown below. |
[[File:ep_3.jpg|800px]] | [[File:ep_3.jpg|800px]] | ||
− | 4) Click on the | + | : 4.) Click on the '''Audio''' button, change the input source to '''Mic''', and click the '''Apply''' button. |
[[File:ep_4.jpg|800px]] | [[File:ep_4.jpg|800px]] | ||
− | 5) Click on the | + | : 5.) Click on the '''Stream''' tab, scroll to the bottom, change the audio format to ''AAC 16 kHz'', change the bitrate to ''96 kbps'', and finally click the '''Apply''' button. |
[[File:ep_5.jpg|800px]] | [[File:ep_5.jpg|800px]] | ||
− | |||
− | |||
− | |||
− |
Latest revision as of 10:50, 31 March 2022
Default IP
By default the all Epiphans can always be accessed by the following IP scheme. Note: If multiple encoders are on the network, your connection might switch between multiple of the encoders.
- IP Address:
192.168.255.250
- Netmask:
255.255.255.252
- User Name:
admin
- Password: your admin password (by default set to no password)
Connect to a New Encoder
To access the VGADVI Broadcaster web interface via the persistent static IP address:
- Record the network settings of the workstation being used to connect to the VGADVI Broadcaster so that they can be restored later.
- Temporarily change the network configuration on the workstation to the following:
- Use Static IP assignment
- IP address:
192.168.255.249
- Subnet mask:
255.255.255.252
- IP address:
- Use Static IP assignment
- Establish an Ethernet connection between the VGADVI Broadcaster and the workstation by one of the following methods:
- Connect the device to a local Ethernet network shared with the workstation.
- Connect the device directly to the workstation’s Ethernet port using either a regular or a crossover Ethernet cable.
- Start a web browser on the workstation and browse to:
http://192.168.255.250/admin/
- Log in as the administrator user with the user name admin and the admin password (by default there is no password); the web interface page opens.
- Click the Networking link in the Configuration menu.
Configuring the Encoder
The following camera settings should be enabled prior to adding the camera to the VALT system.
- 1.) Use the Epiphan Discovery Tool to find the VGABroadcaster device.
- 2.) Click on Web Config using the Discovery tool, or enter the <ipaddress>/admin in a web browser to access the configuration menu. The username should be admin, with a blank password. Click on the Access button.
- 3.) Click on the Network button and select Use Static Address, Set the IP, Network Mask, Gateway & DNS information, then click Apply as shown below.
- 4.) Click on the Audio button, change the input source to Mic, and click the Apply button.
- 5.) Click on the Stream tab, scroll to the bottom, change the audio format to AAC 16 kHz, change the bitrate to 96 kbps, and finally click the Apply button.