Difference between revisions of "VALT Record Button"
IVSWikiBlue (talk | contribs) |
IVSWikiBlue (talk | contribs) |
||
| Line 12: | Line 12: | ||
* [[Start/Stop Button | Installation and Configuration]] | * [[Start/Stop Button | Installation and Configuration]] | ||
| + | * [[VALT Record Button#Technical Specifications|Technical Specifications]] | ||
|right = | |right = | ||
| Line 17: | Line 18: | ||
}} | }} | ||
</onlyinclude> | </onlyinclude> | ||
| + | |||
| + | {{Top of Page}} | ||
| + | {{hr}} | ||
| + | |||
| + | <h1>Technical Specifications</h1> | ||
| + | <table class="price_sheet_table"> | ||
| + | <tr> | ||
| + | <th colspan="2" style="text-align:left; padding-left: 10px">Technical Specifications</th> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="width:180px;font-weight: bold">Installation hole diameter:</td> | ||
| + | <td>22MM</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Head shape:</td> | ||
| + | <td>P-flat head</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Contact type:</td> | ||
| + | <td>1NO</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Operation type:</td> | ||
| + | <td>F-self-resetting (momentary)</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">LED voltage:</td> | ||
| + | <td>12V-DC12V, 24V-DC24V, custom: 5V-DC5V</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Shell material:</td> | ||
| + | <td>S-stainless steel</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Protection level:</td> | ||
| + | <td>Waterproof IP65 (IP68 customizable; button surface will not work if water is present), anti-collision IK10</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Resistive load:</td> | ||
| + | <td>AC-12:220V:2A DC-13:12V/24V:2A</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Inductive load:</td> | ||
| + | <td>AC-12:110V/220V:0.3A DC-13:12V/24V:0.3A</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Contact resistance:</td> | ||
| + | <td><50mΩ</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">LED rated current:</td> | ||
| + | <td><24V,<20mA; >24V,<10mA</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">LED life:</td> | ||
| + | <td>>50000h</td> | ||
| + | </tr> | ||
| + | <tr> | ||
| + | <td style="font-weight: bold">Product certified:</td> | ||
| + | <td>CCC, CE, ROHS (customized), REACH (customized)</td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | {{Top of Page}} | ||
}} | }} | ||
Latest revision as of 11:09, 26 March 2026
VALT Record Button
The VALT Record Button is a simple way to start a recording in or near the room. Simply push the button to start a recording and then push it again to stop the recording.
✎
Since the button does not know who pressed the button, the recording will default authorship to a generic user.
Technical Specifications
| Technical Specifications | |
|---|---|
| Installation hole diameter: | 22MM |
| Head shape: | P-flat head |
| Contact type: | 1NO |
| Operation type: | F-self-resetting (momentary) |
| LED voltage: | 12V-DC12V, 24V-DC24V, custom: 5V-DC5V |
| Shell material: | S-stainless steel |
| Protection level: | Waterproof IP65 (IP68 customizable; button surface will not work if water is present), anti-collision IK10 |
| Resistive load: | AC-12:220V:2A DC-13:12V/24V:2A |
| Inductive load: | AC-12:110V/220V:0.3A DC-13:12V/24V:0.3A |
| Contact resistance: | <50mΩ |
| LED rated current: | <24V,<20mA; >24V,<10mA |
| LED life: | >50000h |
| Product certified: | CCC, CE, ROHS (customized), REACH (customized) |