Difference between revisions of "Biamp Tesira Configuration"

From IVS Wiki
Jump to: navigation, search
(Created page with "== AVB Note == If we are installing one TesiraForte server, and ONLY one remote expander OR a TCM1-A microphone, there is no need for an AVB Extreme switch. If that’s the ca...")
(No difference)

Revision as of 14:04, 16 April 2019

AVB Note

If we are installing one TesiraForte server, and ONLY one remote expander OR a TCM1-A microphone, there is no need for an AVB Extreme switch. If that’s the case, the expander/beamtracking mic will be plugged into the AVB port on the Tesira. Any config with more than a 1:1 ratio of remote devices to Forte servers will require the use of the Extreme switch.

Before Arriving On Site

Determine whether the client wants to access their Tesira from their network, or if it will be a standalone solution. This will change our physical cabling, as well as how we set up the network settings.

Build a Biamp Software Configuration for the job. If possible, test it out in-house with the devices before they are shipped to the customer. This will allow us to give it a live test run, as well as assign the software to the hardware macs before we arrive to install.

AVB Switch

The Extreme switch needs a license and needs to have AVB enabled. If this isn't done before being shipped, we will need to get IVS support to complete. Either a laptop with a serial port or a serial-to-usb adapter will be required. Plug into the Console port on the Extreme switch to perform this task.

On-site Configuration

  1. Physical Installation:
    1. (If it’s a standalone solution with an Extreme switch: Plug both Tesira ports into the Extreme switch, all expanders and beamtracking mics, and our laptop for configuration.)
    2. (If we are using an Extreme switch, and they want the Tesira on their network: The Tesira must be able to talk to any expanders or TCM1-A mics, so the Forte server and the Extreme switch need to be plugged into their network. All the remote devices still plug into the Extreme switch, as will the AVB port on the Tesira.

Software Configuration

  1. Once physically connected, either double click on the config file first (if we did indeed build it ahead of time), or open Biamp software first, either way is fine. (If we open Biamp first, select “Audio Partition”, and select “both Tesira server and TesiraFORTE”).
  2. If need be, upgrade the firmware. Simply Google “Tesira Forte Firmware” and download. Once finished, unpack the zip file so the firmware file is available in the downloads folder. In Tesira, go to Device Maintenance, select the TesiraForte, click Update Firmware, and navigate to the firmware file. Updating firmware takes a good hour or more.
  3. Still on Device Maintenance, click Remote Devices. Click on each one and update their firmware too. (Takes 10+ minutes each).
  4. Head to the Equipment Table (under System; or it’s the little table icon, with 3 bullets and 3 lines).
  5. If nothing is listed, we have to add lines for devices. In the fields in the middle of the Equipment Table, select “Forte” and “Forte CI” or “Remote Expander” and “TCM-1A” or whichever device, then click ADD.
  6. Click on the Tesira server, make sure our server is selected under Host Name. (If we have multiple servers, we can decide where each device is listed. I’d recommend whichever device is physically installed above the other is first in the list, just for our peace of mind. If we need to, press the large button on the front of the Tesira server and it will scroll the serial number briefly.)
  7. Click on the expanders/mics, select one serial number for each device in the Host Name, and select the Tesira server for the Proxy Host Name. (This will tell them all to receive their instructions from the Tesira). Make note of how the devices are numbered in here.
  8. Go to Device Maintenance. Then click Remote Devices.
  9. If it’s helpful we may want to give each expander a description, such as “Room 2200, camera 1 and 2”. (The same is true for the servers, if we have more than one, such as “Tesira for Sim Room” or “Tesira for Observation Rooms”, but that’s on the main Device Maintenance page.) We can also give the remote expanders IP addresses here. The expanders MUST be done first, before changing the IP of the Tesira.
  10. Come back to the Device Maintenance page. Click Network Settings. We’ll need 2 IP addresses for our Tesira; one for Control and one for AVB.
  11. In the Interface ID field, click onto the Media AVB. Click the “Enabled” box. Type in the IP scheme for the AVB port.
  12. Switch back to Control in the Interface ID. Type in the IP scheme for the Control port.
  13. On our Forte and Expander input/output blocks, we’ll notice a number in the upper left-hand corner of each. Make sure they reflect the proper devices (we made note of this info in the Equipment Table). If not, look over on the Properties menu; on the DSP Properties tab, under “Allocated to Unit” select whichever device number is our desired device. Then change “Fixed in Unit” to “True”. This will keep the input/output block from getting another device assigned to it.

Sending a Config to the System

  1. Go to System > Compilation > Compile Active Partition to make sure all paths are connected properly.
  2. Go to System > Network > Send Configuration. The Tesira is basically “empty” until we do this.
  3. It will ask us to name the config; let’s give it a name that makes sense.
  4. Start System Audio: Yes.
  5. Start All. Close.

Now we have a working Tesira Configuration and are live!