Line 78: Line 78:
 
Log into the software with admin rights and navigate to the Admin section then click on Rooms.
 
Log into the software with admin rights and navigate to the Admin section then click on Rooms.
  
[[File:Start_stop_config.png|1500px]]
+
[[File:Start_stop_config.png|1200px|link=https://ipivs.com/wiki/images/c/cd/Start_stop_config.png]]
 
#) Select the room.
 
#) Select the room.
 
#) Check the '''Use I/O''' box.
 
#) Check the '''Use I/O''' box.
Line 95: Line 95:
 
Log into VALT as an admin and click the Admin tab
 
Log into VALT as an admin and click the Admin tab
  
[[File:ValtAdminTab.png|1500px]]
+
[[File:ValtAdminTab.png|1200px|link=https://ipivs.com/wiki/images/9/95/ValtAdminTab.png]]
  
 
Click on Users and Groups and click on the IO Group
 
Click on Users and Groups and click on the IO Group
  
[[File:ValtUserGroups.png|1500px]]
+
[[File:ValtUserGroups.png|1200px|link=https://ipivs.com/wiki/images/1/15/ValtUserGroups.png]]
  
 
Scroll to the bottom and click the Check all on the video access
 
Scroll to the bottom and click the Check all on the video access
  
[[File:ValtVideoAccess.png]]
+
[[File:ValtVideoAccess.png|link=https://ipivs.com/wiki/images/2/2f/ValtVideoAccess.png]]
  
 
==Camera Configuration==
 
==Camera Configuration==

Revision as of 09:07, 1 December 2020

Required Parts and Tools

  • IVS Stop/Start Button
  • 22/4 straight wire cable
  • (1) Single Gang mud ring
  • B-Connectors
  • Wire Crimper
  • Stud finder
  • Fish tape or Glow Rods
  • Face plate screws
  • Small Screwdriver

Hardware Configuration and Wiring

First, wire the button to the desired camera's IO Phoenix connector. If using buttons supplied by IVS, the wires should be connected to the back of the button, as shown in the diagram below.

Current Model

Previous Model (Discontinued)

BTNDiag.jpg

Button Phoenix Connector
NO Pin 1
+ Pin 2
C Pin 3
- Pin 4

Wire Diagrams by Camera

AXIS Cam.png Axis P3235

AXIS Cam.png Axis P3245

AXIS Cam.png Axis P3364/P3365

AXIS Cam.png Axis P3374/P3375

AXIS Cam.png Axis F41

AXIS Cam.png Axis P5414/P5415

AXIS Cam.png Axis M5525

AXIS Cam.png Axis P5635

AXIS Cam.png Axis P5655

AXIS Cam.png Axis V5914/V5915

AXIS Cam.png Axis Q8414

Wire Diagrams by Camera

Axis-camerasmall.png Axis P3235

Axis-camerasmall.png Axis P3245

Axis-camerasmall.png Axis P3364/P3365

Axis-camerasmall.png Axis P3374/P3375

Axis-camerasmall.png Axis F41

Axis-camerasmall.png Axis P5414/P5415

Axis-camerasmall.png Axis M5525

Axis-camerasmall.png Axis P5635

Axis-camerasmall.png Axis P5655

Axis-camerasmall.png Axis V5914/V5915

Axis-camerasmall.png Axis Q8414

Installation Instructions

  1. Determine if the button will be mounted outside or inside the associated room. If mounting near light switches or other control devices, match the mount height of those devices.
  2. Using a stud finder, scan the mounting location of the button to ensure it is not mounted on a stud.
  3. Cut a hole into the drywall, large enough to fit the mud ring into it securely.
    VerifactDring.JPG
  4. Using a hole saw or drywall saw, drill a hole above the drop ceiling in line with the hole drilled where the button is mounted.
  5. Using fish tape or glow rods, pass the 22/4 through the drywall
  6. At the button, use B-Connectors to connect the button
    • Black to Black, White to White, Red to Red, Green to Yellow (please reference camera diagrams above)
  7. At the camera, connect the 18/2 to the I/O port of the camera (please reference camera diagrams above)
  8. Once connected, mount the face plate to the mud ring. Make sure face plate is level
  9. Follow the instructions below to configure the button and click to test.
    StartStopMounted.jpg

Software Configuration

Log into the software with admin rights and navigate to the Admin section then click on Rooms.

Start stop config.png

  1. ) Select the room.
  2. ) Check the Use I/O box.
  3. ) Select what camera the I/O wiring is tied into.
  4. ) Select a user - All I/O recordings in that room will be considered authored by that user.
  5. ) Select Start/Stop in the command field.
  6. ) Enter Port Number 1.
  7. ) Click Add Command.
  8. ) Select Record Indicator in the command field.
  9. ) Enter Port Number 2.
  10. ) If it is a PTZ camera, the camera may be assigned to a preset at the start of the recording.
  11. ) Press Save to enable I/O button recordings.

In the User Groups make sure the I/O User's group has video access to every group

Log into VALT as an admin and click the Admin tab

ValtAdminTab.png

Click on Users and Groups and click on the IO Group

ValtUserGroups.png

Scroll to the bottom and click the Check all on the video access

ValtVideoAccess.png

Camera Configuration

  1. ) Navigate to the IP of the camera.
  2. ) (In the old navigation view) Go to Setup in the top right; then System Options.
  3. ) For Allow Password Type, select Unencrypted Only.
    Start stop unencrypt.png
  4. ) Navigate to Ports & Devices.
  5. ) Change Ports 2 & 4 to Output (if it hasn't already been done).
    Ports old.png
  1. ) (In the new navigation view) Go to Settings; then System; then Plain Config.
    Start stop unencrypt new.png
  2. ) Scroll and select Network.
  3. ) Under HTTP, Authentication Policy, select Basic. Scroll to click Save.
    Start stop unencrypt new 2.png
  4. ) Also head to System > I/O Ports.
    Ports.png
  5. ) Change Port 2 to Output.
    Port 2.png