Difference between revisions of "Encoder Settings"
IVSWikiBlue (talk | contribs) (→Connect to a New Encoder) |
IVSWikiBlue (talk | contribs) |
||
Line 16: | Line 16: | ||
# Temporarily change the network configuration on the workstation to the following: | # Temporarily change the network configuration on the workstation to the following: | ||
#* Use Static IP assignment | #* Use Static IP assignment | ||
− | #* '''IP address:''' <code>192.168.255.249</code> | + | #*# '''IP address:''' <code>192.168.255.249</code> |
− | #* '''Subnet mask:''' <code>255.255.255.252</code> | + | #*# '''Subnet mask:''' <code>255.255.255.252</code> |
# Establish an Ethernet connection between the VGADVI Broadcaster and the workstation by one of the following methods: | # Establish an Ethernet connection between the VGADVI Broadcaster and the workstation by one of the following methods: | ||
#* Connect the device to a local Ethernet network shared with the workstation. | #* Connect the device to a local Ethernet network shared with the workstation. |
Latest revision as of 10:50, 31 March 2022
Default IP
By default the all Epiphans can always be accessed by the following IP scheme. Note: If multiple encoders are on the network, your connection might switch between multiple of the encoders.
- IP Address:
192.168.255.250
- Netmask:
255.255.255.252
- User Name:
admin
- Password: your admin password (by default set to no password)
Connect to a New Encoder
To access the VGADVI Broadcaster web interface via the persistent static IP address:
- Record the network settings of the workstation being used to connect to the VGADVI Broadcaster so that they can be restored later.
- Temporarily change the network configuration on the workstation to the following:
- Use Static IP assignment
- IP address:
192.168.255.249
- Subnet mask:
255.255.255.252
- IP address:
- Use Static IP assignment
- Establish an Ethernet connection between the VGADVI Broadcaster and the workstation by one of the following methods:
- Connect the device to a local Ethernet network shared with the workstation.
- Connect the device directly to the workstation’s Ethernet port using either a regular or a crossover Ethernet cable.
- Start a web browser on the workstation and browse to:
http://192.168.255.250/admin/
- Log in as the administrator user with the user name admin and the admin password (by default there is no password); the web interface page opens.
- Click the Networking link in the Configuration menu.
Configuring the Encoder
The following camera settings should be enabled prior to adding the camera to the VALT system.
- 1.) Use the Epiphan Discovery Tool to find the VGABroadcaster device.
- 2.) Click on Web Config using the Discovery tool, or enter the <ipaddress>/admin in a web browser to access the configuration menu. The username should be admin, with a blank password. Click on the Access button.
- 3.) Click on the Network button and select Use Static Address, Set the IP, Network Mask, Gateway & DNS information, then click Apply as shown below.
- 4.) Click on the Audio button, change the input source to Mic, and click the Apply button.
- 5.) Click on the Stream tab, scroll to the bottom, change the audio format to AAC 16 kHz, change the bitrate to 96 kbps, and finally click the Apply button.