M5525 Shure MX202i W/P
Required Parts And Tools
- Axis M5525
- RDL STM-1
- Shure MX202WP/C Microphone
- Wire Stripper
- Anchors and Screws
- 1/2" paddle bit
- 1 blank single gang wall plate
- Toggle Bolts (If mounting to drop ceiling tile)
- Drill bit and drill
- Phillips head drill bit or Phillips head screwdriver
- Small Flat head screwdriver
- Hole Saw
- B Connectors
- Stud Finder
- Cat5/6 Patch Cable (7ft-15ft recommended)
- 22/2 Gauge Wire
- Fish Tape or Glow Rod
- Wind Screen (Inside MX202i Box)
- Rubber Stopper (Inside MX202i Box)
- 4 pin XLR-M to XLR-M Adapter (Inside MX202i Box)
Connecting the STM-
- Connect MX202WP/C Microphone to the input of the provided wall plate. Connect 22/2 cable to the audio output of that wall plate. VERY IMPORTANT to make the connections AS diagrammed (see below)
- Connect the output 22/2 cable to the input of the STM-1 (Red to +, Black to -, bare wire to ground). Connect 22/2 wire to the power of the STM-1 (red to + and black to -). Connect the other end of that cable to the IO Connectors on the M5525 labeled 12V and GND (Red to 12V and BLK to GND). Using 22/2 cable, connect the red and black to the HI-Z output (red to + black to -). Connect the other end of that cable to the to the IO Connectors on the M5525 labled Audio IN and GND (red to Audio IN and Black to GND)
(NOTE; If there are 2 cameras in the room, duplitcate step 9.1.3 using a long enough cable to get to the 2nd camera. If there are 2 Shure MX202i Microphones, duplicate step 9.1.4.)