  1. Mark center of the ceiling tile the Verifact A will be mounted on.
  2. Using a hole saw, drill a hole at center of the ceiling tile. Feed one end of the the 22/2 cables through the hole.
    Note: Ensure that the hole will be covered by the microphone
    VerifactACutHole.jpg
  3. Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable.
  4. Remove the string and plastic casings covering the red and black cables.
  5. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends. Remove ground.
  6. At the Verifact A, connect the power cable to ports A and C. Connect the audio cable to ports B and C.
    LouroeVerifactAwires2.JPG
  7. Using toggle bolts, secure the microphone.
    VerifactATileMount.jpg