Installing an Axis P3374/P3375 with a Tesira Forte DSP
Revision as of 11:55, 23 April 2020 by IVSWikiBlue (talk | contribs) (Created page with "==Required Parts And Tools== * Axis P3374 or P3375 * 3.5mm (Male to Male) Audio Cable * Louroe Verifact A Microphone * T20 Torx security bit * Wire Stripper *...")
Contents
Required Parts And Tools
- Axis P3374 or P3375
- 3.5mm (Male to Male) Audio Cable
- Louroe Verifact A Microphone
- T20 Torx security bit
- Wire Stripper
- Wall Dogs (if mounting to concrete) (3/16")
- Screws and Anchors (3/16")
- Toggle Bolts (If mounting to drop ceiling tile) (3/16")
- Drill bit and drill
- Phillips head drill bit or Phillips head screwdriver
- Small Flat head screwdriver (#3)
- Cat5/6 Patch Cable (7ft-15ft recommended)
- Shielded Stranded 22/2 + ground Wire
Installation Instructions
- Locate the network drop above the ceiling either being a male Ethernet end (service loop) or a biscuit jack. This will have been ran back to the POE switch. If the switch does not have POE, a POE injector will need to be installed at the network closet.
- Remove the P3374/P3375 camera from its base with the T20 security bit. Using a stud finder, ensure there aren’t any studs where the camera base will be installed. Using a pencil, trace the 2 anchor points on the wall where the screws will be installed and mark the opening where the any cabling will pass through.
- Using a 3/16” drill bit, drill 2 holes at the traced location and insert the plastic anchors. Using the hole saw (recommended size 2”), drill a hole into the area where cables will pass through. Ensure the cut hole does not extend past what the camera dome will cover.
- Using the hole saw, drill a hole above the drop ceiling in line with the hole drilled where the camera will be mounted. If there is no drywall above the ceiling, adjust accordingly to the circumstance.
- Measure and cut 2 lengths of 22/2 wire long enough to reach the destination where the camera is mounted. One cable will be for audio; the other will be to power the Verifact A. Label both ends of each wire accordingly. Using your glow rod or fish tape, fish the network drop and 2 sections of 22/2 audio cable down the drywall.
- Mount the Axis P3374/3375 base to the wall using the screws associated with the anchors.
Connecting the Microphone
Wiring Diagram
Select Optional Second Camera