Template:5655 Installation Instructions

From IVS Wiki
Revision as of 09:33, 27 August 2020 by IVSWikiBlue (talk | contribs) (Installation Instructions)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Installation Instructions

Mounting the Camera

  1. Locate the network drop above the ceiling either being a male Ethernet end (service loop) or a biscuit jack. This will have been ran back to the POE switch.
    Note: If the switch does not have POE, a POE injector will need to be installed at the network closet.
  2. Remove Axis T94A02L kit from packaging. This will include the mounting bracket and the camera dome ring.
  3. Determine the location where the 5655 will be mounted and remove the ceiling tile
  4. Measuring the ceiling mount bracket, note that there is a slight lip to the camera mount
    5635ceiingMount1.jpg
  5. Find center of the ceiling tile and using a pencil, draw a circle approximately nine inches in diameter
  6. Using a drywall saw, cut out the section of ceiling tile where the mount will be inserted
    5635CelingMountInstalled.jpg
  7. Using a T20 bit, tighten the mounting arms of the ceiling mount
    5635celingMountArm.jpg 5635celingMountArmFasten.jpg
    Note: Ensure not to over tighten into the ceiling tile.
  8. Pass the Axis MultiCable C I/O and the Ethernet cable through the hole at the top of the camera mount
    5635CamWire.jpg
  9. Connect cables to their respective ports
    5635CamWireConnect.jpg
  10. Before locking the 5635 to the mounting posts in the ceiling mount, ensure that the safety cable is attached to the camera
    5635safteyWire.jpg 5625safteyPost.jpg
  11. Insert the camera into the ceiling mount and twist until locked in place securely
    5625CameraInstalled.jpg
  12. Using a T20 bit, secure the dome ring to the camera mount
    5635complete.jpg
  13. Carefully return the ceiling tile to its location

Note: If not using drop ceiling, use alternate instructions inside of the box for mounting to a hard ceiling.

Connecting Wiring

  1. Begin but cutting two lengths of 22/2. Ensure they are long enough to reach the microphone location. One will be for audio signal. One will be for power.
  2. Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable.
  3. Remove the string and plastic casings covering the red and black cables.
  4. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends. Remove ground.
  5. At the Axis MultiCable C I/O, connect the ends of 22/2
    • Audio will be connected to the "In" on the audio terminal block - Red to +, Black to -
    • Power will be connected to the I/O terminal block - Red to to 2, Black to 1
    5635MulitCableConnect.jpg