==Required Parts And Tools==
 
==Required Parts And Tools==
 +
 
* Axis F41 Main Unit
 
* Axis F41 Main Unit
*:[[File:Axis F41.jpg|60x80px]]
 
 
* Axis F1005
 
* Axis F1005
*:[[File:Axis F1005 SENSOR.png|60x80px]]
 
 
* Axis F8001
 
* Axis F8001
*:[[File:Axis F8001.png|60x80px]]
 
* Louroe IFPX
 
*:[[File:IFPX.JPG|60x80px]]
 
 
* 3.5mm (Male to Male) Audio Cable
 
* 3.5mm (Male to Male) Audio Cable
* Louroe Verifact A Microphone  
+
* Louroe Verifact A Microphone               
*:[[File:Verifact-A.JPG|60x80px]]              
+
* T20 Torx security bit
* S2 TT10 Torx security bit
+
* Wire Stripper
* Wire Stripper  
+
* Tap-Cons (if mounting to concrete) (3/16")
*:[[File:Wire_Stripper_and_Starbit_Driver.JPG|60x80px]]
+
* Screws and Anchors (3/16")
* Wall Dog Screw Anchors
 
*:[[File:Wall-Dog Screw Anchor.jpg|60x80px]] 
 
 
* Toggle Bolts (If mounting to drop ceiling tile)  
 
* Toggle Bolts (If mounting to drop ceiling tile)  
*:[[File:Toggle_Bolts.JPG|60x80px]]
 
 
* Drill bit and drill  
 
* Drill bit and drill  
*:[[File:Drill_and_Brill_Bits.JPG|60x80px]]
 
 
* Phillips head drill bit or Phillips head screwdriver
 
* Phillips head drill bit or Phillips head screwdriver
* Small Flat head screwdriver  
+
* Small Flat head screwdriver (#3)
*:[[File:Small_Flathead_Screwdriver.JPG|60x80px]]
 
 
* Cat5/6 Patch Cable (7ft-15ft recommended)  
 
* Cat5/6 Patch Cable (7ft-15ft recommended)  
*:[[File:Cat6_Patch_Cable.JPG|60x80px]] 
+
* Stranded Shielded 22/2 + ground Wire
* 22/2 Gauge Wire  
 
*:[[File:Audio_Cable.JPG|60x80px]]
 
 
 
==Installation Instructions==
 
 
 
#Locate the network drop above the ceiling either being a male Ethernet end (service loop) or a biscuit jack. This will have been ran back to the POE switch. If the switch does not have POE, a POE injector will need to be installed at the network closet.
 
#Using the T10 bit, remove the rubber feet from the bottom of the Axis F41 Main Unit, and replace it with the Axis F8001. This will allow the F41 to be mounted to drywall above the drop ceiling.
 
#Find the a suitable mounting location for the F41. Using four anchors and screws (or wall dogs), mount the F41 into the drywall above the drop ceiling. (Note, if there is no drop ceiling make other arrangements for mounting.)
 
#Connect the network drop to the Axis F41 Main Unit. When connected, the '''NET''', '''STATUS''', and '''POWER''' LEDs will show green on the unit. After approximately one minute, all three indicators should be green. If not, troubleshoot connections.
 
#Assemble the mounting unit for the Axis F1005. Mount the camera into the drop ceiling using toggle bolts. Run the attached RJ-11 cable to the input labeled '''CAM''' on the Axis F41 Main Unit. Ensure to drill an appropriate hole in the drop ceiling to feed the RJ-11 cable through.
 
#:[[File:Axis F1005 Mounted.jpg|400x300px]] [[File:F41 Fully wired.jpg|400x300]]
 
  
==Connecting the Microphone==
+
{{F41 F1005 Installation Instructions}}
  
#Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable. Remove the string and plastic casings covering the red and black cables. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends (See picture)
+
{{F41 VerifactA}}
#:[[File:Stripped_22_2_Wire.JPG|400x300px]]
 
#Drill a hole into the piece of ceiling tile that you will be mounting the Louroe Verifact-A. Feed one end of the the 22/2 audio cable through the hole. Connect the audio cable to the Verifact-A phoenix terminal as follows; Red to A, Black to B, Common (bare wire) to C (See Picture). Using Toggle bolts, secure the Verifact-A to the drop ceiling tile.
 
#:[[File:Wired_Verifact_A.JPG|400x300px]]
 
#:[[File:Wired_up_IFPX.JPG|400x300px]]
 
#Connect the other end of your 22/2 cable to the terminal on the IFPX labeled '''MIC/SPEAKER A B C SP'''. The connections will be as follows: Red to A, Black to B, Common (bare wire) to C (See Picture)
 

Latest revision as of 10:25, 18 May 2020

Wiring Diagram

Click to Expand

Select Optional Second Camera

AXIS Cam.png Axis P3235

AXIS Cam.png Axis P3245

AXIS Cam.png Axis P3364/P3365

AXIS Cam.png Axis P3374/P3375

AXIS Cam.png Axis Axis F41

AXIS Cam.png Axis P5414/P5415

AXIS Cam.png Axis Axis M5525

AXIS Cam.png Axis Axis P5635

AXIS Cam.png Axis P5655

AXIS Cam.png Axis V5914/V5915

AXIS Cam.png Axis Q8414

Required Parts And Tools

  • Axis F41 Main Unit
  • Axis F1005
  • Axis F8001
  • 3.5mm (Male to Male) Audio Cable
  • Louroe Verifact A Microphone
  • T20 Torx security bit
  • Wire Stripper
  • Tap-Cons (if mounting to concrete) (3/16")
  • Screws and Anchors (3/16")
  • Toggle Bolts (If mounting to drop ceiling tile)
  • Drill bit and drill
  • Phillips head drill bit or Phillips head screwdriver
  • Small Flat head screwdriver (#3)
  • Cat5/6 Patch Cable (7ft-15ft recommended)
  • Stranded Shielded 22/2 + ground Wire

Installation Instructions

Mounting the Processing Unit

  1. Locate the network drop above the ceiling. It should be terminated with a male Ethernet end (service loop) or a biscuit jack. This line will have been ran back to the POE switch.
    Note: If the switch does not have POE, a POE injector will need to be installed at the network closet.
  2. Using the T20 bit, remove the rubber feet from the bottom of the Axis F41 Main Unit, and replace it with the Axis F8001. This will allow the F41 to be mounted to drywall above the drop ceiling.
    F41RubberFootPlate.jpg F41-8001btm.jpg F41-8001top.jpg
  3. Find the a suitable mounting location for the F41. Using a pencil, mark the location the four anchors will be mounted
  4. Using a drill and drill bit, drill the mounting locations.
  5. Insert the four anchors and screws (or wall dogs), and mount the F41 into the drywall above the drop ceiling.
    Note: if there is no drop ceiling make other arrangements for mounting.
    F41Anchors.jpg
    F41Mounted.jpg
  6. Connect the network drop to the Axis F41 Main Unit. When connected, the NET, STATUS, and POWER LEDs will show green on the unit. After approximately one minute, all three indicators should be green.
    F41-intialNet.jpg F41-confirmNet.jpg

Mounting the Camera

  1. Assemble the mounting unit for the Axis F1005.
  2. Mount the camera into the drop ceiling using toggle bolts.
  3. Run the attached RJ-11 cable to the input labeled CAM on the Axis F41 Main Unit. Ensure to drill an appropriate hole in the drop ceiling to feed the RJ-11 cable through.
    Axis F1005 Mounted.jpg

Connecting the Microphone

  1. Mark center of the ceiling tile the Verifact A will be mounted on.
  2. Using a hole saw, drill a hole at center of the ceiling tile. Feed one end of the the 22/2 cables through the hole.
    Note: Ensure that the hole will be covered by the microphone
    VerifactACutHole.jpg
  3. Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable.
  4. Remove the string and plastic casings covering the red and black cables.
  5. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends. Remove ground.
  6. At the Verifact A, connect the power cable to ports A and C. Connect the audio cable to ports B and C.
    LouroeVerifactAwires2.JPG
  7. Using toggle bolts, secure the microphone.
    VerifactATileMount.jpg
  8. Connect the other ends of the 22/2 cable to the terminals on F41.
  • The audio line will be connected to a 3.5mm audio cable (cut approx. 12") with B-connectors and inserted in the "Audio In" port
  • Power will be connected to the I/O connector (Black to 1, Red to 2)
F41CompleteWiring.jpg