Installing an Axis F41 and Axis F1005 sensor unit with a Louroe Verifact A Microphone

From IVS Wiki
Revision as of 16:19, 17 April 2020 by IVSWikiBlue (talk | contribs) (Wiring Diagram)
Jump to: navigation, search

Required Parts And Tools

  • Axis F41 Main Unit
  • Axis F1005
  • Axis F8001
  • 3.5mm (Male to Male) Audio Cable
  • Louroe Verifact A Microphone
  • T10 Torx security bit
  • Wire Stripper
  • Wall Dogs (if mounting to concrete) (3/16")
  • Screws and Anchors (3/16")
  • Toggle Bolts (If mounting to drop ceiling tile)
  • Drill bit and drill
  • Phillips head drill bit or Phillips head screwdriver
  • Small Flat head screwdriver (#3)
  • Cat5/6 Patch Cable (7ft-15ft recommended)
  • Stranded Shielded 22/2 + ground Wire

Installation Instructions

  1. Locate the network drop above the ceiling either being a male Ethernet end (service loop) or a biscuit jack. This will have been ran back to the POE switch. If the switch does not have POE, a POE injector will need to be installed at the network closet.
  2. Using the T10 bit, remove the rubber feet from the bottom of the Axis F41 Main Unit, and replace it with the Axis F8001. This will allow the F41 to be mounted to drywall above the drop ceiling.
  3. Find the a suitable mounting location for the F41. Using four anchors and screws (or wall dogs), mount the F41 into the drywall above the drop ceiling. (Note, if there is no drop ceiling make other arrangements for mounting.)
  4. Connect the network drop to the Axis F41 Main Unit. When connected, the NET, STATUS, and POWER LEDs will show green on the unit. After approximately one minute, all three indicators should be green. If not, troubleshoot connections.
  5. Assemble the mounting unit for the Axis F1005. Mount the camera into the drop ceiling using toggle bolts. Run the attached RJ-11 cable to the input labeled CAM on the Axis F41 Main Unit. Ensure to drill an appropriate hole in the drop ceiling to feed the RJ-11 cable through.
    Axis F1005 Mounted.jpg 400x300

Connecting the Microphone

  1. Begin by cutting two lengths of 22/2. One will be for audio. One will be for power
  2. Strip the jacket off the 22/2, revealing the red and black wires. Remove the string and ground wire. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends (See picture)
    Stripped 22 2 Wire.JPG
  3. Drill a hole into the piece of ceiling tile that you will be mounting the Louroe Verifact-A. Feed one the 22/2 cable through the hole. Connect the audio cable to the Verifact-A phoenix terminal as follows; Audio cable to A and C; Power to B and C(See Picture). Using Toggle bolts, secure the Verifact-A to the drop ceiling tile.
    Wired Verifact A.JPG
  4. Connect the other end of your 22/2 cable to the terminal on F41. The audio line will be connected to a 3.5mm audio cable (cut approx. 12") with B-connectors. Power will be connected to the I/O connector (Black to 1, Red to 2)

Wiring Diagram

Select Optional Second Camera

AXIS Cam.png Axis P3235

AXIS Cam.png Axis P3245

AXIS Cam.png Axis P3364/P3365

AXIS Cam.png Axis P3374/P3375

AXIS Cam.png Axis Axis F41

AXIS Cam.png Axis P5414/P5415

AXIS Cam.png Axis Axis M5525

AXIS Cam.png Axis Axis P5635

AXIS Cam.png Axis P5655

AXIS Cam.png Axis V5914/V5915

AXIS Cam.png Axis Q8414