Difference between revisions of "Installing an Axis F41 and Axis F1025 sensor unit with a Louroe Verifact D Microphone"

From IVS Wiki
Jump to: navigation, search
(Installation Instructions)
(Connecting the Microphone)
Line 47: Line 47:
 
==Connecting the Microphone==
 
==Connecting the Microphone==
  
#Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable. Remove the string and plastic casings covering the red and black cables. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends (See picture)
+
#Cut two lengths of 22/2. One will be for power. One will be for audio signal. Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable. Remove the string and plastic casings covering the red and black cables. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends (See picture).
 
#:[[File:Stripped_22_2_Wire.JPG|400x300px]]
 
#:[[File:Stripped_22_2_Wire.JPG|400x300px]]
#Cut a hole into the drywall, large enough to fit the mud ring into it securely.  Feed one end of the the 22/2 audio cable through the hole. (If mounting on a hard surface, attached Datacom box to the wall). Connect the audio cable to the Verifact-D phoenix terminal as follows; Red to A, Black to B, Common (bare wire) to C (See Picture)
+
#Cut a hole into the drywall, large enough to fit the mud ring into it securely.  Feed one end of the the 22/2 audio cable through the hole. (If mounting on a hard surface, attached Datacom box to the wall). If mounting to ceiling tile, mark center on the drop ceiling tile and trace the location of the mud ring. Using a dry wall saw, cut out the mud ring location. When securing the mud ring, be careful not to over tighten. Connect the audio cable to the Verifact-D phoenix terminal as follows; Red to A, Black to B, Common (bare wire) to C (See Picture)
 
#:[[File:Verifact-D_wired_up.JPG|400x300px]]
 
#:[[File:Verifact-D_wired_up.JPG|400x300px]]
#Connect the other end of your 22/2 cable to the terminal on the IFPX labeled '''MIC/SPEAKER A B C SP'''. The connections will be as follows; Red to A, Black to B, Common (bare wire) to C (See Picture)
+
#Connect the other end of the 22/2 cables to the ports on the F41 unit. The cable for audio will be connected to a 3.5mm cable with wire crimps. The power cable will be connected to the I/O port (Red to 2, Black to 1)
#:[[File:Wired_up_IFPX.JPG|400x300px]]
+
#Use the 3.5mm Male to Male audio cable and connect it into the “AUDIO IN” on the Axis F41 Main Unit. Using wire crimps, this will be connected with the 22/2 line ran from the Verifact D (See Picture)  
 +
#:[[File:F41 No Cam Wired.jpg|400x300]]
 
#Align Verifact-D with mud ring or Datacom box and screw in securely.
 
#Align Verifact-D with mud ring or Datacom box and screw in securely.

Revision as of 10:45, 7 April 2020

Required Parts And Tools

  • Axis F41 Main Unit
    Axis F41.jpg
  • Axis F1025
    Axis F1025.jpg
  • Axis F8001
    Axis F8001.png
  • 3.5mm (Male to Male) Audio Cable
  • Louroe Verifact D Microphone
    Verifact-D.JPG
  • S2 TT10 Torx security bit
  • Wire Stripper
    Wire Stripper and Starbit Driver.JPG
  • Wall Dog Screw Anchor
    Wall-Dog Screw Anchor.jpg
  • Anchors and Screws
    Screws and Anchors.JPG
  • Toggle Bolts (If mounting to drop ceiling tile)
    Toggle Bolts.JPG
  • Drill bit and drill
    Drill and Brill Bits.JPG
  • Phillips head drill bit or Phillips head screwdriver
  • Small Flat head screwdriver
    Small Flathead Screwdriver.JPG
  • Cat5/6 Patch Cable (7ft-15ft recommended)
    Cat6 Patch Cable.JPG
  • 22/2 Gauge Wire
    Audio Cable.JPG
  • 2 Mud rings if mounting Verifact D Mic to drywall, Datacom box if mounting to hard surface (ex. Cinderblock)
    Mud Ring.JPG Datacom box.JPG
  • Drywall Saw
    DryWall Saw.JPG
  • 1 blank single gang wall plate with 1/4" cut hole
    Blankplate.JPG

Installation Instructions

  1. Locate the network drop above the ceiling either being a male Ethernet end (service loop) or a biscuit jack. This will have been ran back to the POE switch. If the switch does not have POE, a POE injector will need to be installed at the network closet.
  2. Using the T10 bit, remove the rubber feet from the bottom of the Axis F41 Main Unit, and replace it with the Axis F8001. This will allow the F41 to be mounted to drywall above the drop ceiling.
  3. Find the a suitable mounting location for the F41. Using four anchors and screws (or wall dogs), mount the F41 into the drywall above the drop ceiling. (Note, if there is no drop ceiling make other arrangements for mounting.)
  4. Connect the network drop to the Axis F41 Main Unit. When connected, the NET, STATUS, and POWER LEDs will show green on the unit. After approximately one minute, all three indicators should be green. If not, troubleshoot connections.
    400x300
  5. Cut a hole into the drywall, large enough to fit the mud ring into it securely. (If mounting on a hard surface, attach Datacom box to the wall). Run the attached RJ-11 cable behind the drywall to the input labeled CAM on the Axis F41 Main Unit.
  6. 400x300
  7. Mount Axis F1025 to single gang wall plate, aligning the camera with the center cut hole. Once established, secure the faceplate to the mud ring.

Connecting the Microphone

  1. Cut two lengths of 22/2. One will be for power. One will be for audio signal. Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable. Remove the string and plastic casings covering the red and black cables. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends (See picture).
    Stripped 22 2 Wire.JPG
  2. Cut a hole into the drywall, large enough to fit the mud ring into it securely. Feed one end of the the 22/2 audio cable through the hole. (If mounting on a hard surface, attached Datacom box to the wall). If mounting to ceiling tile, mark center on the drop ceiling tile and trace the location of the mud ring. Using a dry wall saw, cut out the mud ring location. When securing the mud ring, be careful not to over tighten. Connect the audio cable to the Verifact-D phoenix terminal as follows; Red to A, Black to B, Common (bare wire) to C (See Picture)
    Verifact-D wired up.JPG
  3. Connect the other end of the 22/2 cables to the ports on the F41 unit. The cable for audio will be connected to a 3.5mm cable with wire crimps. The power cable will be connected to the I/O port (Red to 2, Black to 1)
  4. Use the 3.5mm Male to Male audio cable and connect it into the “AUDIO IN” on the Axis F41 Main Unit. Using wire crimps, this will be connected with the 22/2 line ran from the Verifact D (See Picture)
    400x300
  5. Align Verifact-D with mud ring or Datacom box and screw in securely.