Installing Williams Talkback on Axis Cameras with C I/O Connector
Required Parts And Tools
- Axis P5635, P5414/15-E
- Williams Talkback System IR T1
- Williams RX224 Receiver
- 22/2 audio cable
- Fish Tape or Glow Rod
- Electrical Tape
- Wire Stripper
Installation Instructions
- Once your camera is installed, locate the AUDIO OUT on your P5635 Multicable.
- Strip the jacket of the 22/2 cable revealing the red, black, and bare wires inside. Cut away the bare wire and plastic surround the cable inside. Strip away a small piece of the red and black jackets revealing the bare copper wire.
- Wire the black and ground to the - and the red to the + of the AUDIO OUT of the Multicable or phoenix connector.
- Run your 22/2 cable to the IR T1.
- Strip about an inch of white jacket off the 22/2, as well as about 1/2 inch of the colored jackets to expose the wire. Cut a 3.5mm cable open, test for continuity, then splice it with the 22/2 with B-connectors. Cover your splice with electrical tape.
- Plug the 3.5 cable into the Line In of the IR T1.
- Once audio is plugged in, locate your nearest power outlet to power the IR T1. You may need to use 18/2 cable to add length to the power cable. Ensure that when splicing in the 18/2 to the power, that the red jacket of the 18/2 is spliced into the cable with the dashed white lines on the power supply. Ensure your IR T1 and RX224 are set to the same channel. Test the talkback unit is working by activating the talkback function within the VALT Software and having a partner use their computer microphone to communicate with you.