Installing an Axis P3245 with a Louroe Verifact A Microphone

From IVS Wiki
Jump to: navigation, search

Wiring Diagram

Click to Expand

Select Optional Second Camera

AXIS Cam.png Axis P3235

AXIS Cam.png Axis P3245

AXIS Cam.png Axis P3364/P3365

AXIS Cam.png Axis P3374/P3375

AXIS Cam.png Axis Axis F41

AXIS Cam.png Axis P5414/P5415

AXIS Cam.png Axis Axis M5525

AXIS Cam.png Axis Axis P5635

AXIS Cam.png Axis P5655

AXIS Cam.png Axis V5914/V5915

AXIS Cam.png Axis Q8414

Required Parts and Tools

  • Axis P3245-LV
  • Louroe Verifact A Microphone
  • T20 Torx security bit
  • Wire Stripper
  • Tapcons (if mounting to concrete) (3/16")
  • Screws and Anchors (3/16")
  • Toggle bolts (If mounting to drop ceiling tile) (3/16")
  • Paddle bit (1-2")
  • Toggle Bolts (for mic mount) (3/16")
  • Drill bit and drill
  • Phillips head drill bit or Phillips head screwdriver
  • Small Flat head screwdriver
  • Hole Saw (2")
  • B Connectors
  • Stud Finder
  • Cat5/6 Patch Cable (7ft-15ft recommended)
  • Shielded Stranded 22/2 + ground Wire
  • Fish Tape or Glow Rods

Installation Instructions

Disassemble the Camera

  1. Locate the network drop above the ceiling. It should be terminated with a male Ethernet end (service loop) or a biscuit jack. This line will have been ran back to the POE switch.
    Note: If the switch does not have POE, a POE injector will need to be installed at the network closet.
  2. Using the T20 bit, remove the dome from the 3245.
    3245UnassembledDome.jpg
  3. Remove the camera from the mounting plate.
    3245MountPlate.jpg

Mount the Camera

Drywall mounting instructions

  1. Using a stud finder, scan the mount location to ensure the camera is not mounted on a stud.
  2. Using a pencil, mark the four holes for the mount plate.
  3. Using a 3/16" drill bit, drill the marked locations and
  4. Install anchors and attach the mount plate using screws and washers.
    3245Drywall2.JPG
  5. Using a hole saw or paddle bit, cut a hole centered in the wall plate where cables will pass through.
    3245DrywallHole2.JPG
  6. Using the hole saw, drill a hole above the drop ceiling in line with the hole drilled where the camera is mounted.
  7. Cut two lengths of 22/2 long enough to reach the mounting location of the microphone.
  8. Using glow rods or fish tape, fish the network drop or patch cable in addition to the two sections of 22/2 audio cable through the drywall.
  9. Attach the camera the the mount plate
    3245DrywalPlate2.JPG

Drop Ceiling mount instructions

  1. If mounting to drop ceiling, determine where the camera will be located on the tile. Ensure that there will be clearance on the tile to secure the dome in place.
  2. Using two toggle bolts, secure the mount plate.
    3245dropC2.JPG
  3. Using a 1" paddle bit, drill a hole centered in the opening of wall plate. This is where cables will pass through.
    3245dropCHole2.JPG
  4. Cut two lengths of 22/2 long enough to reach the mounting location of the microphone.
  5. Using glow rods or fish tape, fish the network drop and 2 sections of 22/2 audio cable into the drop ceiling.
  6. Attach camera to mount plate.
    3245DropCDome.jpg

Note: Be careful not to press too hard and damage the ceiling tile

Connect Wiring

  1. Connect patch cable into the Ethernet port on the Axis P3245.
    Note: When connected, activity will be visible on the link lights. If no link lights appear, ensure that POE is enabled on the POE switch and that the network drop is plugged in. After approximately one minute, all three LEDs should be green.
  2. At the camera, connect the power cable to the I/O phoenix connector (Red to 2, Black to 1). Connect the audio cable to the audio terminal block (Red to 3, Black to 1)
    3245 audio2.jpg 3245power2.jpg

Aim the Camera

  1. In order to aim the camera, it will need to be accessed via the Axis web portal.
  2. If the camera is being powered off the network, run Axis IP utility in order to discover the camera. Clicking the IP address will route to the Axis web portal
    IPutility.jpg
  3. If that does not work then use a POE injector to connect to the camera and the default IP. (default Axis IP = 192.168.0.90)
  4. Using a laptop/PC, enter the IP address assigned to the camera into a web browser.
    WebPortalLogIn.jpg
  5. Using the IVS admin credentials, log into the camera.
    User: root
    Password: admin51
  6. Once in the Axis web portal, activate the camera live view.
    PreLiveMode.jpg Liveview.jpg
  7. Begin by manually adjusting camera's viewing area using the manual tilt and focus mechanisms on the camera.
    3245Adjustments.jpg
  8. Using the digital zoom function in the web portal, make any other adjustments needed.
  9. The image field may also be rotated in the web portal if necessary.
    LiveviewRotate.jpg
  10. Be sure to click the Autofocus button. This will focus the camera and ensure that the autofocus is properly functioning.
    LiveAutoFocus.jpg
    Note: This must be done before securing the dome.

Reassemble the Camera

  1. Remove protective film before securing dome
  2. Place the dome over on the camera. Using the T20 bit, tighten the dome cover in place.
  3. Snap the Axis dome ring into the base plate

Connecting the Microphone

  1. Mark center of the ceiling tile the Verifact A will be mounted on.
  2. Using a hole saw, drill a hole at center of the ceiling tile. Feed one end of the the 22/2 cables through the hole.
    Note: Ensure that the hole will be covered by the microphone
    VerifactACutHole.jpg
  3. Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable.
  4. Remove the string and plastic casings covering the red and black cables.
  5. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends. Remove ground.
  6. At the Verifact A, connect the power cable to ports A and C. Connect the audio cable to ports B and C.
    LouroeVerifactAwires2.JPG
  7. Using toggle bolts, secure the microphone.
    VerifactATileMount.jpg