Difference between revisions of "Output Channel Selector Kit"

From IVS Wiki
Jump to: navigation, search
(Required Parts and Tools)
(Wiring the ST-RX2)
Line 22: Line 22:
 
[[File:Db-rc2st wiring.png|link=https://ipivs.com/wiki/images/a/ad/Db-rc2st_wiring.png]]
 
[[File:Db-rc2st wiring.png|link=https://ipivs.com/wiki/images/a/ad/Db-rc2st_wiring.png]]
 
==Wiring the ST-RX2==  
 
==Wiring the ST-RX2==  
#
+
#Determine above the ceiling where the ST-RX2 will be mounted
#
+
#Connect the lines ran from the DB-RC2ST as shown
#
+
[[File:St-RX2 wiring2.png|link=https://ipivs.com/wiki/images/e/e1/St-RX2_wiring2.png]]
 +
 
 +
''Note:'' The ST-RX2 and DB-RC2ST will draw from the same power source and can be connected together using a terminal block
 +
 
 
==Device Data Sheets==
 
==Device Data Sheets==

Revision as of 10:20, 15 February 2021

Wiring Diagram

Required Parts and Tools

  • RDL ST-RX2
  • RDL D-RT2ST
  • RDL 24 V power supply
  • (1) terminal block
  • Shielded Stranded 22/2 + ground Wire
  • (1) Single Gang mud ring or triple gang if paired with observation audio kit(s)
  • Stud finder
  • Fish tape or Glow Rods
  • Drywall Saw
  • Small Screwdriver
  • Face plate screws

Mounting the Button

  1. Using a stud finder, scan the mounting location of the Verifact D ensure the microphone is not mounted on a stud.
  2. Using a pencil, mark out where the switching button will be located
  3. Cut a hole into the drywall, large enough to fit the mud ring into it securely.
    VerifactDring.JPG
  4. Cut a hole above the drop ceiling to fish lines (if necessary)
  5. Using fish tape or glow rods, fish 3 lines of 22/2, two for signal control and one for power. (shown below)

Db-rc2st wiring.png

Wiring the ST-RX2

  1. Determine above the ceiling where the ST-RX2 will be mounted
  2. Connect the lines ran from the DB-RC2ST as shown

St-RX2 wiring2.png

Note: The ST-RX2 and DB-RC2ST will draw from the same power source and can be connected together using a terminal block

Device Data Sheets