Difference between revisions of "Output Channel Selector Kit"

From IVS Wiki
Jump to: navigation, search
(Wiring the ST-RX2)
(Mounting the Button)
Line 14: Line 14:
  
 
== Mounting the Button==
 
== Mounting the Button==
#Using a stud finder, scan the mounting location of the Verifact D ensure the microphone is not mounted on a stud.
+
#Using a stud finder, scan the mounting location of the DB-RC2ST to ensure the device is not mounted on a stud.
 
#Using a pencil, mark out where the switching button will be located  
 
#Using a pencil, mark out where the switching button will be located  
 
#Cut a hole into the drywall, large enough to fit the mud ring into it securely.   
 
#Cut a hole into the drywall, large enough to fit the mud ring into it securely.   
Line 21: Line 21:
 
#Using fish tape or glow rods, fish 3 lines of 22/2, two for signal control and one for power. (shown below)  
 
#Using fish tape or glow rods, fish 3 lines of 22/2, two for signal control and one for power. (shown below)  
 
[[File:Db-rc2st wiring.png|link=https://ipivs.com/wiki/images/a/ad/Db-rc2st_wiring.png]]
 
[[File:Db-rc2st wiring.png|link=https://ipivs.com/wiki/images/a/ad/Db-rc2st_wiring.png]]
 +
#Once the lines are ran, mount the selector to the mud ring
 +
#Gently secure the face plate once mounted
 +
 
==Wiring the ST-RX2==  
 
==Wiring the ST-RX2==  
 
#Determine above the ceiling where the ST-RX2 will be mounted  
 
#Determine above the ceiling where the ST-RX2 will be mounted  

Revision as of 10:24, 15 February 2021

Wiring Diagram

Required Parts and Tools

  • RDL ST-RX2
  • RDL D-RT2ST
  • RDL 24 V power supply
  • (1) terminal block
  • Shielded Stranded 22/2 + ground Wire
  • (1) Single Gang mud ring or triple gang if paired with observation audio kit(s)
  • Stud finder
  • Fish tape or Glow Rods
  • Drywall Saw
  • Small Screwdriver
  • Face plate screws

Mounting the Button

  1. Using a stud finder, scan the mounting location of the DB-RC2ST to ensure the device is not mounted on a stud.
  2. Using a pencil, mark out where the switching button will be located
  3. Cut a hole into the drywall, large enough to fit the mud ring into it securely.
    VerifactDring.JPG
  4. Cut a hole above the drop ceiling to fish lines (if necessary)
  5. Using fish tape or glow rods, fish 3 lines of 22/2, two for signal control and one for power. (shown below)

Db-rc2st wiring.png

  1. Once the lines are ran, mount the selector to the mud ring
  2. Gently secure the face plate once mounted

Wiring the ST-RX2

  1. Determine above the ceiling where the ST-RX2 will be mounted
  2. Connect the lines ran from the DB-RC2ST as shown

St-RX2 wiring2.png

Note: The ST-RX2 and DB-RC2ST will draw from the same power source and can be connected together using a terminal block

Device Data Sheets