Difference between revisions of "Installing an Axis P3235 with a Louroe Verifact D Microphone"

From IVS Wiki
Jump to: navigation, search
(Required Parts And Tools)
(Installation Instructions)
Line 25: Line 25:
  
 
#Locate the network drop above the ceiling either being a male Ethernet end (service loop) or a biscuit jack. This will have been ran back to the POE switch. If the switch does not have POE, a POE injector will need to be installed at the network closet.
 
#Locate the network drop above the ceiling either being a male Ethernet end (service loop) or a biscuit jack. This will have been ran back to the POE switch. If the switch does not have POE, a POE injector will need to be installed at the network closet.
#Connect the network drop into the RJ-45 on the Axis P3245. When connected, activity will be visible on the link lights. If no link lights appear, ensure that POE is enabled on the POE switch and that the network drop is plugged in. After approximately one minute, all 3 should be green. If not, check connections.
+
#Connect the network drop into the Ethernet port on the Axis P3245. When connected, activity will be visible on the link lights. If no link lights appear, ensure that POE is enabled on the POE switch and that the network drop is plugged in. After approximately one minute, all three LEDs should be green. If not, troubleshoot connections.
 
#Mount your Axis P3235 to either the wall below (using anchors and screws), or the drop ceiling tile (using the toggle bolts).
 
#Mount your Axis P3235 to either the wall below (using anchors and screws), or the drop ceiling tile (using the toggle bolts).
 +
#Cut two similar lengths of 22/2. One will be for audio. One will be for power
 +
#Cut a hole into the drywall, large enough to fit the mud ring into it securely.  Feed one end of the the 22/2 audio cables and patch cable through the hole. (If mounting on a hard surface, attached Datacom box to the wall). Connect the 22/2 cables to the Verifact-D phoenix terminal as follows; Audio - Red to B, Black to C, Power - Red to A, Black to C (See Picture).
 
#Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable. Remove the string and plastic casings covering the red and black cables. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends (See picture)
 
#Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable. Remove the string and plastic casings covering the red and black cables. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends (See picture)
 
#:[[File:Stripped_22_2_Wire.JPG|400x300px]]
 
#:[[File:Stripped_22_2_Wire.JPG|400x300px]]
#Cut a hole into the drywall, large enough to fit the mud ring into it securely.  Feed one end of the the 22/2 audio cable through the hole. (If mounting on a hard surface, attached Datacom box to the wall). Connect the audio cable to the Verifact-D phoenix terminal as follows;; Red to A, Black to B, Common (bare wire) to C (See Picture)
+
#Connect the other ends of the 22/2 cables to the P3235 camera. The connections will be as follows; '''Audio''' - Black to 1, Red to 3 on audio terminal block, '''Power''' - Black to 1, Red to 3 on I/O terminal block
#:[[File:Verifact-D_wired_up.JPG|400x300px]]
 
#Connect the other end of the 22/2 cable to audio phoenix connector on the P3235 camera. The connections will be as follows; Common (bare wire) to 1, Red to 2, Black to 3, (See Picture)
 
#:[[File:P3235_wiring.jpg|400x300px]]
 
 
#Place the dome over on the camera. Using the T20 bit, tighten the dome cover in place.
 
#Place the dome over on the camera. Using the T20 bit, tighten the dome cover in place.
 
#Align Verifact-D with mud ring or Datacom box and screw in securely.
 
#Align Verifact-D with mud ring or Datacom box and screw in securely.

Revision as of 11:11, 14 April 2020

Required Parts And Tools

  • Axis P3235
  • 3.5mm (Male to Male) Audio Cable
  • Louroe Verifact D Microphone
  • 1 Mud ring if mounting to drywall, Datacom box if mounting to hard surface (ex. Cinderblock)
  • S2 TT20 Torx security bit
  • Wire Stripper
  • Anchors and Screws (If wall mounted)
  • Toggle bolts (If mounting to drop ceiling tile)
  • 1/2" paddle bit
  • 3.5mm Audio Cable
  • Toggle Bolts for mic mount
  • Drill bit and drill
  • Phillips head drill bit or Phillips head screwdriver
  • Small Flat head screwdriver
  • Hole Saw
  • B Connectors
  • Stud Finder
  • Cat5/6 Patch Cable (7ft-15ft recommended)
  • Shielded Stranded 22/2 + ground Wire
  • Fish Tape or Glow Rods

Installation Instructions

  1. Locate the network drop above the ceiling either being a male Ethernet end (service loop) or a biscuit jack. This will have been ran back to the POE switch. If the switch does not have POE, a POE injector will need to be installed at the network closet.
  2. Connect the network drop into the Ethernet port on the Axis P3245. When connected, activity will be visible on the link lights. If no link lights appear, ensure that POE is enabled on the POE switch and that the network drop is plugged in. After approximately one minute, all three LEDs should be green. If not, troubleshoot connections.
  3. Mount your Axis P3235 to either the wall below (using anchors and screws), or the drop ceiling tile (using the toggle bolts).
  4. Cut two similar lengths of 22/2. One will be for audio. One will be for power
  5. Cut a hole into the drywall, large enough to fit the mud ring into it securely. Feed one end of the the 22/2 audio cables and patch cable through the hole. (If mounting on a hard surface, attached Datacom box to the wall). Connect the 22/2 cables to the Verifact-D phoenix terminal as follows; Audio - Red to B, Black to C, Power - Red to A, Black to C (See Picture).
  6. Strip the jacket off the 22/2, revealing the red, black, and common (bare wire) on both sides of the cable. Remove the string and plastic casings covering the red and black cables. Strip the red and black jackets off the wire exposing the copper. Cut copper evenly on both ends (See picture)
    Stripped 22 2 Wire.JPG
  7. Connect the other ends of the 22/2 cables to the P3235 camera. The connections will be as follows; Audio - Black to 1, Red to 3 on audio terminal block, Power - Black to 1, Red to 3 on I/O terminal block
  8. Place the dome over on the camera. Using the T20 bit, tighten the dome cover in place.
  9. Align Verifact-D with mud ring or Datacom box and screw in securely.